Check of monitoring and basic settings
This page describes how to check that
- No error messages are received at start up
- The monitoring works
- The database works and contains test data
Do following in a browser:
Start Program
Go to http://$GUIadminserver:$http-port/HarvestDefinition/
- where GUIadminserver and http-port are specified in the deploy configuration file under the application named dk.netarkivet.common.webinterface.GUIApplication
In the one-machine setup (deploy_example_one_machine.xml ) the link will be : http://localhost:8074
Check that JMX works
Click 'Systemstate'->'Overview of the system state'
- Check that all internally developed applications are up and running
- Check that last status message for each application do not contain errors or warnings
- Check that there are no empty log messages
- Click on an physical location in the 'Location' column e.g. "K"
- Check that you now only see relevant SW applications for the chosen organisation
- Click 'Show all' in the 'Location' header
- Check that you return to the full listening again
- Repeat the above 4 steps ’Machine ", "HTTP Port", "Application", "Instance Id", "Priority", "Use Replica" and "Index" (Index shows all log lines in the given appl. log)
- The Instance ID column in the System overview GUI is a technical suffix to the Application column to separate more than one Application of the same type on the same server. If there is only 1 Application on a server it will normally be empty. If there is more than 1 Application of the same type on the same server, there must be added a suffix i.e. an Instance ID. It is userdefined (in the deploy script) and must be unique.
Click 'Systemstate' -> 'Overview of the system state'
- Check that you are back to the full overview with log line 0
Check that basic database data is present
Click 'Definitions'->'Find Domain(s)'
- Search for =netarkivet.dk= by writing this text and click 'Search'
- Check that the GUI returns a result-set of one, namely the domain =netarkivet.dk=
- Click on the link =netarkivet.dk=, and the page for domain =netarkivet.dk= should be shown without errors
- Click 'Edit' on the line configuration line for defaultconfig
- Check that Name is "defaultconfig"
- Check that Harvest template is "default_orderxml"
- Check that Maximum number of objects is "2.000"
- Check that Maximum number of bytes is "500.000.000"
Check that mail recipients specified in the start of this test receive no error mails
- Check that there are no mails with error messages about non-existing files
- Check that there are no mails with error messages about applications that could not be started